MAIL
You might also like:
Autoblog,
Autoblog Green,
and More
More Links
AOL Weather
DailyFinance
Engadget
FanHouse
JSYK
AOL Television
Philanthropy
Switched
WalletPop
PopEater
Asylum
MovieFone
Main
Ask
Sign Up
Explore
You aren't signed in
Sign In
More
sdanglergj99
Send a private message
Member Since July 11, 2008 , From
gRAND JUNCTION
,
United States
Ask
Ask
Liked this profile? Tell your friends about it
Facebook
Windows Live
Yahoo
Twitter
Digg
Google
del.icio.us
Reddit
Link
Embed
Copy and paste the text above to share this Q&A
Recent Activity by sdanglergj99
All
My Answers (61)
My Questions (1)
My Comments (0)
I am Watching (0)
I was Asked (0)
Answered:
I'm trying to wire thermostat for bryant heat pump ...
In a heat pump your Y1 call is heat, and when in cooling mode the tstat energizes O. From the outdoor unit hook the white wire to the W terminal on indoor unit. I have never jumped y and w on the ...
Posted 4 years ago
Answered:
My 2 story home is approximately 2200 sq ft. How ...
Not enough info.... (sun exposure, insulation type and value, ceiling heights, window types... and many other's) never always go by the old 500sqf per ton method.
Posted 4 years ago
Answered:
My builder provided me with a 10 yr parts and ...
There is probably a leak in the linesets and they are in a wall or inaccesible. My thoughts are there has been no coil leaks and they are just trying to get through the warranty period. Pay to have ...
Posted 4 years ago
Answered:
My central air unit continuously runs. I have had ...
Could be sized wrong also..... Shardee is right though try to get a tech that is NATE certified...... Any bozo can get a refrigerant license and say they can work on A/C systems, but NATE techs have ...
Posted 4 years ago
Answered:
Replacing a compressor
Yes and No........ SEER rating is effected by the capacity of the system. Generally changing the compressor wil not change the seer rating, and if you do not have the proper equipment (recovery ...
Posted 4 years ago
Answered:
Heat pump going into defrost when in cooling mode
Defrost mode on a heat pump is cooling mode......... You must have a tempering kit that fires your secondary or supplemental heat........ replacing the defrost timer or board should work, but really ...
Posted 4 years ago
Answered:
Need to choose heating and air system to ...
Have used all the above, Trane is best.... Goodman ranks on the low side with Ruud. In 2010 they are phasing out r-22.........
Posted 4 years ago
Answered:
In the cold-air duct system of force air ...
Depends.... If in a mobile home, you must leave in place and should be set at at least half way. If in a standard home it can be remove.... I would suggest putting an actuated damper and an FRV ...
Posted 4 years ago
Answered:
Saving on Home Heating Costs in Winter
Humid air feels warmer and retains more heat......... Maybe, I have found that humidity levels around 35 to 40 percent are best.
Posted 4 years ago
Answered:
Gas furnace igniter tubes won't light.....
Depends on the age of the system. Is the gas valve actuating? Is there pressure switches (is the flue blocked) is the inducer fan running? Need more info to help
Posted 4 years ago
1
2
3
4
5
6
7
Next
Subscribe to "sdanglergj99's Activity on AOL Answers"
Activity Summary
Last 7 Days Activity
All Time Activity
Questions
Answers
Helpful
First to Answer
Comments
0
0
0
0
0
1
61
6
56
0
Topics of Interest
construction
fish
air conditioning
Contacts
sdanglergj99 has no contacts.
Compliments
sdanglergj99 will review your compliment before it's published for everyone to see.
* Please avoid HTML or links
Take a sec and thank sdanglergj99 for helping
No compliments were posted on sdanglergj99's profile yet.
About
Feedback
Terms of Use
Privacy Policy
Copyright 2012 Yedda Inc an AOL Company and respective copyright owners
Member Since #since#
Last 7 Days Activity
All Time Activity
Questions
Answers
Helpful
First to Answer
Comments
More